Weidmüller 1067250000 Analogue Signal Conditioning,signal converter and process monitoring – ACT20P,Bridge measuring transducer
Configuration DIP switch and button Linearity Typically ± 0.05 % of signal range Long-term drift 0.1 % / 10.000 h
Weidmüller 1175980000 Analogue Signal Conditioning,Space-saving signal converter – ACT20M,Signal converters
Accuracy < 0.05 % of measuring range Configuration none Galvanic isolation 3-way isolator Power consumption, max. 0.8 W Power consumption, typ.
Weidmüller 1175990000 Analogue Signal Conditioning,Space-saving signal converter – ACT20M,Signal splitter
Accuracy < 0.05 % of measuring range Configuration none Galvanic isolation 3-way isolator Power consumption, max. 0.8 W Power consumption, typ.
Weidmüller 1176000000 Analogue Signal Conditioning,Space-saving signal converter – ACT20M,Signal converters
Accuracy < 0.05 % of measuring range Configuration DIP switch Delivery state Setting parameters Input Configuration 0…20 mA Setting parameters
Weidmüller 1176010000 Analogue Signal Conditioning,Space-saving signal converter – ACT20M,Signal converters
Accuracy < 0.2 % of measuring range Configuration DIP switch Delivery state Setting parameters Input Configuration 0…20 mA Setting parameters
Weidmüller 1176020000 Analogue Signal Conditioning,Space-saving signal converter – ACT20M,Signal splitter
Accuracy < 0.05 % of measuring range Configuration DIP switch Delivery state Setting parameters Input Configuration 0…20 mA (loop) Setting
Weidmüller 1176030000 Analogue Signal Conditioning,Space-saving signal converter – ACT20M,Universal converter
Accuracy < 0.1 % of measuring range Configuration With FDT/DTM software Galvanic isolation 3-way isolator Power consumption, max. 1.2 W Power
Weidmüller 1176040000 Analogue Signal Conditioning,Space-saving signal converter – ACT20M,Passive isolator
Accuracy < 0.05 % of measuring range Configuration none Galvanic isolation 2-way isolator Power consumption, max. 0.5 W Rail TS 35
Weidmüller 1176050000 Analogue Signal Conditioning,Space-saving signal converter – ACT20M,Passive isolator
Accuracy < 0.05 % of measuring range Configuration none Galvanic isolation 2-way isolator Power consumption, max. 50 kByte Rail TS 35
Weidmüller 1176070000 Analogue Signal Conditioning,Space-saving signal converter – ACT20M,Passive isolator
Accuracy < 0.1 % of measuring range Configuration none Galvanic isolation 2-way isolator Power consumption 30 mW per channel Rail
Weidmüller 1176080000 Analogue Signal Conditioning,Space-saving signal converter – ACT20M,Passive isolator
Accuracy < 0.1 % of measuring range Configuration none Galvanic isolation 2-way isolator Power consumption 30 mW per channel Rail
Weidmüller 1282490000 Analogue Signal Conditioning,Accessories,ACT20 (incl. DIN rail bus & powersupplies)
Degree of efficiency 100 % Rail TS 35, CH20M Bus Type of connection Screw connection Voltage supply 21.6…26.4 V DC
Weidmüller 1318220000 Analogue Signal Conditioning, intrinsically safe signal converter – ACT20X,HART® transparent driver
Accuracy < 0.1 % of end value Configuration With FDT/DTM software Humidity 10…90 %, no condensation Power consumption ≤ 3.5
Weidmüller 1335140000 Component housings,Mounting rail bus system – CH20M,CH20M BUS SET – Kit
Height 6.2 mm Height (inches) 0.244 °C Width 25.1 mm Width (inches) 0.988 °C Length 250 mm Length (inches) 9.842 °C Net weight 47.21 g
Weidmüller 1375450000 Analogue Signal Conditioning,Space-saving signal converter – ACT20M,Signal converters
Accuracy < 0.05 % of measuring range Configuration DIP switch Delivery state Setting parameters Bandwidth Configuration 100 Hz Setting parameters
Weidmüller 1375470000 Analogue Signal Conditioning,Space-saving signal converter – ACT20M,Signal splitter
Accuracy < 0.05 % of measuring range Configuration DIP switch Delivery state Setting parameters Bandwidth Configuration 100 Hz Setting parameters
Weidmüller 1375480000 Analogue Signal Conditioning,Space-saving signal converter – ACT20M,Temperature transducer
Accuracy absolute accuracy: < ±0.05 % of the measurement range, Basic accuracy: < ±0.5° Configuration DIP switch Delivery state Setting
Weidmüller 1375510000 Analogue Signal Conditioning,Space-saving signal converter – ACT20M,Temperature transducer
Accuracy absolute accuracy: < ±0.05 % of the measurement range, Basic accuracy: < ±0.1°C Configuration DIP switch Delivery state Setting
Weidmüller 1375520000 Analogue Signal Conditioning,Space-saving signal converter – ACT20M,Temperature transducer
Accuracy absolute accuracy: < ±0.1 % of the measurement range Configuration DIP switch Delivery state Setting parameters Output Configuration 4…20
Weidmüller 1435590000 Analogue Signal Conditioning,Space-saving signal converter – ACT20M,Temperature transducer
Accuracy absolute accuracy: < ±0.05 % of the measurement range, RTD (PT100) Basic accuracy: < ±0.1 °C of the measurement
Weidmüller 1435610000 Analogue Signal Conditioning,Space-saving signal converter – ACT20M,Temperature transducer
Accuracy absolute accuracy: < ±0.1 % of the measurement range, Basic accuracy: < ±0.2°C Cold-junction compensation error ±(2.0 °C +
Weidmüller 1453210000 Analogue Signal Conditioning,signal converter and process monitoring – ACT20P,Universal
Accuracy < 0.1 % of measuring range Cold-junction compensation error ±1.0°C @ -20° C – 65°C Configuration With FDT/DTM software
Weidmüller 1477420000 Analogue Signal Conditioning,signal converter and process monitoring – ACT20P,Universal
Configuration DIP switch, Keys and LED display, with reference voltage/current sources Galvanic isolation 3-way isolator, between input ⁄ output ⁄
Weidmüller 1481970000 Analogue Signal Conditioning,signal converter and process monitoring – ACT20P,Universal
Accuracy < 0.05 % of measuring range Configuration DIP switch, or via display and push-buttons Galvanic isolation 3-way isolator, between