101 sonuçtan 1-24 arası gösteriliyor

Filtreleri Göster
Yer tutucu
Kapat

Weidmüller 1067250000 Analogue Signal Conditioning,signal converter and process monitoring – ACT20P,Bridge measuring transducer

Configuration DIP switch and button Linearity Typically ± 0.05 % of signal range Long-term drift 0.1 % / 10.000 h
Yer tutucu
Kapat

Weidmüller 1175980000 Analogue Signal Conditioning,Space-saving signal converter – ACT20M,Signal converters

Accuracy < 0.05 % of measuring range Configuration none Galvanic isolation 3-way isolator Power consumption, max. 0.8 W Power consumption, typ.
Yer tutucu
Kapat

Weidmüller 1175990000 Analogue Signal Conditioning,Space-saving signal converter – ACT20M,Signal splitter

Accuracy < 0.05 % of measuring range Configuration none Galvanic isolation 3-way isolator Power consumption, max. 0.8 W Power consumption, typ.
Yer tutucu
Kapat

Weidmüller 1176000000 Analogue Signal Conditioning,Space-saving signal converter – ACT20M,Signal converters

Accuracy < 0.05 % of measuring range Configuration DIP switch Delivery state Setting parameters Input Configuration 0…20 mA Setting parameters
Yer tutucu
Kapat

Weidmüller 1176010000 Analogue Signal Conditioning,Space-saving signal converter – ACT20M,Signal converters

Accuracy < 0.2 % of measuring range Configuration DIP switch Delivery state Setting parameters Input Configuration 0…20 mA Setting parameters
Yer tutucu
Kapat

Weidmüller 1176020000 Analogue Signal Conditioning,Space-saving signal converter – ACT20M,Signal splitter

Accuracy < 0.05 % of measuring range Configuration DIP switch Delivery state Setting parameters Input Configuration 0…20 mA (loop) Setting
Yer tutucu
Kapat

Weidmüller 1176030000 Analogue Signal Conditioning,Space-saving signal converter – ACT20M,Universal converter

Accuracy < 0.1 % of measuring range Configuration With FDT/DTM software Galvanic isolation 3-way isolator Power consumption, max. 1.2 W Power
Yer tutucu
Kapat

Weidmüller 1176040000 Analogue Signal Conditioning,Space-saving signal converter – ACT20M,Passive isolator

Accuracy < 0.05 % of measuring range Configuration none Galvanic isolation 2-way isolator Power consumption, max. 0.5 W Rail TS 35
Yer tutucu
Kapat

Weidmüller 1176050000 Analogue Signal Conditioning,Space-saving signal converter – ACT20M,Passive isolator

Accuracy < 0.05 % of measuring range Configuration none Galvanic isolation 2-way isolator Power consumption, max. 50 kByte Rail TS 35
Yer tutucu
Kapat

Weidmüller 1176070000 Analogue Signal Conditioning,Space-saving signal converter – ACT20M,Passive isolator

Accuracy < 0.1 % of measuring range Configuration none Galvanic isolation 2-way isolator Power consumption 30 mW per channel Rail
Yer tutucu
Kapat

Weidmüller 1176080000 Analogue Signal Conditioning,Space-saving signal converter – ACT20M,Passive isolator

Accuracy < 0.1 % of measuring range Configuration none Galvanic isolation 2-way isolator Power consumption 30 mW per channel Rail
Yer tutucu
Kapat

Weidmüller 1282490000 Analogue Signal Conditioning,Accessories,ACT20 (incl. DIN rail bus & powersupplies)

Degree of efficiency 100 % Rail TS 35, CH20M Bus Type of connection Screw connection Voltage supply 21.6…26.4 V DC
Yer tutucu
Kapat

Weidmüller 1318220000 Analogue Signal Conditioning, intrinsically safe signal converter – ACT20X,HART® transparent driver

Accuracy < 0.1 % of end value Configuration With FDT/DTM software Humidity 10…90 %, no condensation Power consumption ≤ 3.5
Yer tutucu
Kapat

Weidmüller 1335140000 Component housings,Mounting rail bus system – CH20M,CH20M BUS SET – Kit

Height 6.2 mm Height (inches) 0.244 °C Width 25.1 mm Width (inches) 0.988 °C Length 250 mm Length (inches) 9.842 °C Net weight 47.21 g  
Yer tutucu
Kapat

Weidmüller 1375450000 Analogue Signal Conditioning,Space-saving signal converter – ACT20M,Signal converters

Accuracy < 0.05 % of measuring range Configuration DIP switch Delivery state Setting parameters Bandwidth Configuration 100 Hz Setting parameters
Yer tutucu
Kapat

Weidmüller 1375470000 Analogue Signal Conditioning,Space-saving signal converter – ACT20M,Signal splitter

Accuracy < 0.05 % of measuring range Configuration DIP switch Delivery state Setting parameters Bandwidth Configuration 100 Hz Setting parameters
Yer tutucu
Kapat

Weidmüller 1375480000 Analogue Signal Conditioning,Space-saving signal converter – ACT20M,Temperature transducer

Accuracy absolute accuracy: < ±0.05 % of the measurement range, Basic accuracy: < ±0.5° Configuration DIP switch Delivery state Setting
Yer tutucu
Kapat

Weidmüller 1375510000 Analogue Signal Conditioning,Space-saving signal converter – ACT20M,Temperature transducer

Accuracy absolute accuracy: < ±0.05 % of the measurement range, Basic accuracy: < ±0.1°C Configuration DIP switch Delivery state Setting
Yer tutucu
Kapat

Weidmüller 1375520000 Analogue Signal Conditioning,Space-saving signal converter – ACT20M,Temperature transducer

Accuracy absolute accuracy: < ±0.1 % of the measurement range Configuration DIP switch Delivery state Setting parameters Output Configuration 4…20
Yer tutucu
Kapat

Weidmüller 1435590000 Analogue Signal Conditioning,Space-saving signal converter – ACT20M,Temperature transducer

Accuracy absolute accuracy: < ±0.05 % of the measurement range, RTD (PT100) Basic accuracy: < ±0.1 °C of the measurement
Yer tutucu
Kapat

Weidmüller 1435610000 Analogue Signal Conditioning,Space-saving signal converter – ACT20M,Temperature transducer

Accuracy absolute accuracy: < ±0.1 % of the measurement range, Basic accuracy: < ±0.2°C Cold-junction compensation error ±(2.0 °C +
Yer tutucu
Kapat

Weidmüller 1453210000 Analogue Signal Conditioning,signal converter and process monitoring – ACT20P,Universal

Accuracy < 0.1 % of measuring range Cold-junction compensation error ±1.0°C @ -20° C – 65°C Configuration With FDT/DTM software
Yer tutucu
Kapat

Weidmüller 1477420000 Analogue Signal Conditioning,signal converter and process monitoring – ACT20P,Universal

Configuration DIP switch, Keys and LED display, with reference voltage/current sources Galvanic isolation 3-way isolator, between input ⁄ output ⁄
Yer tutucu
Kapat

Weidmüller 1481970000 Analogue Signal Conditioning,signal converter and process monitoring – ACT20P,Universal

Accuracy < 0.05 % of measuring range Configuration DIP switch, or via display and push-buttons Galvanic isolation 3-way isolator, between